Scenario S-7 · Perry's Awesomeness Factory (Building B)

Dropped drum of still bottoms at the HWA

90-day hazardous waste area (HWA), Building B south.

Day and time
Friday, 10:30 p.m.
Material
Hazardous Waste, D001: spent Thunderbolt and R-101 still bottoms
How much is out
About 5 gallons.
Weather and wind
52 °F, clear. Wind from the southwest at 5 mph.

The scene

It is Friday, 10:30 at night, night shift in Perry's Awesomeness Factory, Building B. Two operators are moving the last drum of still bottoms for the week into the 90-day hazardous waste area on a drum cart. The 55-gallon steel drum is about two-thirds full. It slides off the cart, lands on its side, and the bung pops out. About 5 gallons are on the floor and it is still trickling out, spreading toward the other D001 drums. It is a dark puddle with a strong solvent smell. The two operators back off and radio Marty McFly. Buildings A and C are closed. Outside it is 52 degrees and clear, with the wind from the southwest at 5 miles an hour.

Scene facts

Tap a heading to open it.

When, where and what

Day, time and shiftFriday, 10:30 p.m. Building B night shift.
Where90-day hazardous waste area (HWA), Building B south. PI-B-101 grid E3.
Inside or outsideInside.
What spilled (name on the label)Hazardous Waste, D001: spent Thunderbolt and R-101 still bottoms.
What it was inDrum (55-gallon steel, bung top).
How much the container holds55 gallons. This drum was about two-thirds full, about 36 gallons.
Who was there and what they were doingTwo night shift operators were moving the week's last drum of still bottoms into the HWA on a drum cart.
What happenedThe drum slid off the cart, landed on its side, and the bung popped out.
How much is outAbout 5 gallons.
Is it still leaking?Yes. A steady trickle from the open bung.
What it spilled onConcrete floor.
Which way it is runningSpreading across the HWA floor toward the other D001 drums.
What you see right nowA dark puddle about 5 ft across. Strong solvent odor. The drum cart is tipped over next to the drum.
Did anyone get it on them?No.
People on site right nowBuilding B: about 28 (night shift), including 5 ERT members. Gate 2 security. Buildings A and C are closed.
Weather and wind52 °F, clear. Wind from the southwest at 5 mph.
What is nearbyRows of D001 drums on containment pallets. Caustic washwater tank TK-HW1. Spill kit SK-5. Door B-4. Packaging to the west, Lab/QC to the east.
What has been done so far, and who has been calledThe two operators backed off and radioed Marty McFly.

Plans and SDS

These are the plans that apply to this scene. Read them to find what to do.

Maps

The red circle marks the spill. Tap a drawing to open it full size, then zoom in. The enlarged view has its own graphic scale in feet.

scenario s 7 zoom
PI-B-101 — enlarged view
scenario s 7 b
PI-B-101 — full drawing
scenario s 7 campus