Scenario S-10 · Perry's Awesomeness Factory (Building B)

Transformer oil leak after a tornado warning

Transformer TX-2, south of Building B.

Day and time
Monday, 3:25 p.m.
Material
Transformer mineral oil
How much is out
About 20 gallons inside the pad curb.
Weather and wind
Storm has passed. 66 °F, overcast, wet. Wind from the northwest at 15 mph.

The scene

It is Monday afternoon. At 3:08 a tornado warning is issued for Tiberius County, take cover is sounded, and everyone shelters. The all-clear comes at 3:20. Building B night shift is on, Building A is in, and Building C is open until 3:30. Utility power is out and GEN-1 is running. At 3:25, a maintenance mechanic walking the south side of Perry's Awesomeness Factory, Building B, finds a light pole down across transformer TX-2. TX-2 is tilted and leaking transformer oil from a seam. About 20 gallons are floating on rainwater inside the pad curb, and the rainwater is about 6 inches deep. A power line is down across the South Drive near SI-2. Building C's headcount is one driver short, last seen in his tractor in the yard. The storm has passed. It is 66 degrees and overcast, with the wind from the northwest at 15 miles an hour.

Scene facts

Tap a heading to open it.

When, where and what

Day, time and shiftMonday, 3:25 p.m. Building B night shift (started 2:30). Building A days. Building C open until 3:30.
WhereTransformer TX-2, south of Building B. PI-B-101 grid F3.
Inside or outsideOutside.
What spilled (name on the label)Transformer mineral oil.
What it was inTransformer TX-2 on a curbed concrete pad.
How much the container holds200 gallons.
Who was there and what they were doingNobody. A tornado warning was issued at 3:08 p.m.; take cover was sounded and everyone sheltered. The all-clear was given at 3:20. A maintenance mechanic found the damage on a walk-around.
What happenedA light pole blew down across TX-2 and tilted it.
How much is outAbout 20 gallons inside the pad curb.
Is it still leaking?Yes. A slow seep from a seam on the transformer.
What it spilled onConcrete pad with a 12-inch curb, holding rainwater.
Which way it is runningFloating on the rainwater inside the curb. The rainwater is about 6 inches deep.
What you see right nowDark oil floating on rainwater inside the curb. The light pole is lying across TX-2. Utility power is out; GEN-1 is running. A power line is down across the South Drive near SI-2.
Did anyone get it on them?No.
People on site right nowBuilding B: about 28 (night shift), including 5 ERT members. Building A: about 18. Building C: about 24 plus drivers; the Building C headcount is short one driver, last seen in his tractor in the yard.
Weather and windStorm has passed. 66 °F, overcast, wet. Wind from the northwest at 15 mph.
What is nearbyTX-1 on the next pad. GEN-1 and its base tank T-4. Storm inlet SI-2. Spill kit SK-6. The South Drive. Doors B-4 and B-5. Storm debris.
What has been done so far, and who has been calledTake cover and the all-clear were sounded by the control room. The mechanic radioed the control room about TX-2.

Plans and SDS

These are the plans that apply to this scene. Read them to find what to do.

Your instructor will give you the SDS for this material.

Maps

The red circle marks the spill. Tap a drawing to open it full size, then zoom in. The enlarged view has its own graphic scale in feet.

scenario s 10 zoom
PI-B-101 — enlarged view
scenario s 10 b
PI-B-101 — full drawing
scenario s 10 campus
PI-C-001 — campus site plan